ABB S800 I/O System of all modules

  • Warranty: 365 days
  • Quality: Original module
  • Condition: New / Used
  • Warehouse: Spot
  • Delivery time: Shipped in 3 days after payment
  • Mailbox:panda@xiongbaindustrial.com

.Many products are not yet on the shelves please contact us for more products

.If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation

.We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible


ABB S800 I/O System of all modulesABB S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers over industry-standard field buses. Thanks to its broad connectivity it fits a wide range of process controllers from ABB and other vendors.


By permitting installation in the field, close to sensors and actuators, S800 I/O reduces the installation cost by reducing the cost of cabling. And thanks to features such as “hot swap” of modules, “on-line” reconfiguration and redundancy options, it contributes to keeping production-and thereby profits-up.





CI801, S800L I/O, TB825,TB826

CI810

CI820, TB815

CI840A Redundant Comm. Modules

Compact I/O

Redundant I/O

Intrinsic safety I/O

Extended I/O


General specifications

Communication interfaces

CI810 For Advant Fieldbus 100. Supports dual bus-cable redundancy. With AC 400 series controllers. 

CI801 For PROFIBUS-DP/V1. Hot Configuration in Run & HART pass-through. GSD-file provided. 

TB820V2 Optical cluster modem for Modulebus/drives integration. 

TB825 Optical media converter. Multimode up to 1 000 meter. 

TB826 Long range optical media converter. Single mode up to 5 000 meter. 

TB810 / 811 / 842 Modulebus optical port.


Redundant interface

CI820 For redundant Advant Fieldbus 100 in combination with Advant Controller 400 series controllers. 

TB815 Interconnection Unit. An electrical and optical Modulebus interface for coordination of the two parallell CI820 needed. 

CI840A For redundant PROFIBUS-DP/V1. Hot Configuration in Run & HART pass-through. GSD file provided. 

TB840A Optical cluster modem for redundant optical Modulebus. Installed on TU840/TU841/TU848/TU849. Use TU807 for single configuration. Used with AC 800M. Hot Conf In Run, HART pass-through and Sequence of Events. Installation on vertical DIN rail.


Module Termination Units (MTU:s)

TU810V1 With screw terminals 

TU812V1 With 25 pin D-sub connector 

TU814V1 With 3 crimp snap-in connectors 

TU818 With screw terminals 

TU819 With dual 25 pin D-sub

TU811V1 With screw terminals 

TU813 With 3 crimp snap-in connectors


Compact for intrinsic safety

TU89X With screw terminals & isolated power supply


Extended, 50 V applications

TU830V1 / TU835V1 / TU838 / TU850 With screw terminals, pwr. distribution & fuse 

TU833 With spring-cage term., pwr. distribution & fuse 

TU834 With screw terminals for shunt sticks, TY80X

TU831V1 / TU836V1 / TU837V1 / TU839 / TU851 With screw terminals, pwr. distribution & fuse

TU842 / 843 (horiz./vert. mounting) with screw terminals 

TU844 / 845 (horiz./vert. mounting) with screw terminals and shunt sticks, TY80X 

TU852 / 854 (horiz./ver. mounting) with 25 pin D-subs and shunt sticks, TY80X

TU805 For DI801 & DO801. With field power distribution screw terminals


S800 I/O modules

Digital input modules

DI810 Digital input. 16 ch., 2 groups of 8 ch., 24 V d.c., current sink. 

DI811 Digital input. 16 ch., 2 groups of 8 ch., 48 V d.c., current sink. 

DI814 Digital input. 16 ch., 2 groups of 8 ch., 24 V d.c., current source. 

DI818 Digital input. 32 ch., 2 groups of 16 ch., 24 V d.c., current sink. 

DI820 Individually galvanic isolated channels. 8 ch., separate returns, 110 V d.c., 120 V a.c. 

DI821 Individually galvanic isolated channels. 8 ch., separate returns, 220 V d.c., 230 V a.c. 

DI825 Individually galvanic isolated channels with SOE (Sequence Of Events). 8 ch., separate returns, 125 V d.c. 

DI828 Digital input. 16 ch., separate returns, 110 V d.c., 120 V a.c / d.c. 

DI830 With SOE (Sequence Of Events). 16 ch., 2 groups of 8 ch., 24 V d.c., current sink. Event recording resolution: <0.5 ms. 

DI831 With SOE (Sequence Of Events). 16 ch., 2 groups of 8 ch., 48 V d.c., current sink. Event recording resolution: <0.5 ms. 

DI885 With SOE (Sequence Of Events) & wire-fault detection. 8 ch., 1 group of 8 ch., 24-48 V d.c., current sink. Event recording resolution: 1 ms.


Pulse input module

DP820 Individually galvanic isolated channels. 2 ch., separate returns, signal voltage: RS422/5 V/12 V/24 V/13 mA d.c., freq. measurement or pulse counting 0.25 Hz - 1.5 MHz


Digital output modules

DO810 Digital output. 16 ch., 2 groups of 8 ch., 24 V d.c., max 0.5 A, transistor, current source, short-circuit-proof. 

DO814 Digital output. 16 ch., 2 groups of 8 ch., 24 V d.c., max 0.5 A, transistor, current sink, short-circuit-proof. 

DO815 With wire-fault detection. 8 ch., 2 groups of 4 ch., 24 V d.c., max 2 A, transistor, current source, short-circuit-proof. 

DO818 Digital output. 32 ch., 2 groups of 16 ch., 24 V d.c., max 0.5 A, transistor, current source, short-circuit-proof .

DO820 Individually galvanic isolated channels. 8 ch., separate returns, 5-250 V, max 3 A a.c./d.c., relay (N.O.). 

DO821 Individually galvanic isolated channels. 8 ch., separate returns, 5-250 V, max 3 A a.c./d.c., relay (N.C.). 

DO828 Individually galvanic isolated channels. 16 ch., separate returns, 5-250V a.c. / 5-125V d.c. max 2A a.c./d.c., relay (N.O.).


Analog input modules

AI810 Analog input. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA, 0(2)-10 V, 12 bits. 

AI815 With HART interface. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA 0(1)-5 V, 12 bits, HART interface, transmitter power supply. 

AI820 Differential inputs. 4 ch., 1 group of 4 ch., bipolar differential, ±0(1)-5 V, ±0(2)-10 V, ±0(4)-20 mA, 14 bits + sign. 

AI825 Individually galvanic isolated channels. 4 ch., separate returns, isolated bipolar, ±0(2)-10 V, ±0(4)-20 mA, 14 bits + sign. 

AI830A RTD inputs with wire-fault detection. 8 ch., 1 group of 8 ch., Pt100, Ni100, Ni120, Cu10, resistor 0-400 Ω, 14 bits, 3-wire. 

AI835A TC inputs with open circuit detection. 8 ch., (7+ ref. junction), 1 group of 8 ch., TC types B, C, D, E, J, K, L, N, R, S, T, U, -30…75 mV, 15 bits.


Analog output modules

AO810V2 With open circuit detection. 8 ch., 1 group of 8 ch., 0(4)-20 mA, 14 bits, load: max 850 Ω (short-circuit-proof). 

AO815 With HART interface and open circuit detection. 8 ch., 1 group of 8 ch., 4..20 mA, 12 bit, load: max 750 Ω (short-circuit-proof ), HART interface. 

AO820 Individually galvanic isolated channels with open circuit detection 4 ch., separate returns, isolated bipolar, ±0(2)-10 V, ±0(4)-20 mA, 12 bits + sign, load: max 550 Ω (current) / ≥2 kΩ (voltage), short-circuit-proof.


I/O modules with intrinsic-safety interface

DI890 Individually galvanic isolated digital input channels with wire-fault detection. 8 ch., separate returns, 24 V d.c., current sink. 

DO890 Individually galvanic isolated digital output channels with wire-fault detection. 4 ch., separate returns, 11 V @ 40 mA, load 150-5000 Ω, current source, short circuit-proof. 

AI890 Analog inputs. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA, 12 bits, transmitter power supply 

AI893 TC/RTD inputs with wire-fault detection. 8 ch. (7 + ref. junction), 1 group of 8 ch., TC types B, C, E, J, K, L, N, R, S, T, U, -10…80 mV. RTD: Pt50- 1000, Ni100-500, Cu10-100, resistor 0-4000 Ω, 3-wire. 15 bits + sign. 

AI895 Analog inputs with HART interface. 8 ch., 1 group of 8 ch., single ended with common return, 4-20 mA, 12 bits, HART interface, transmitter power supply. 

AO890 Analog outputs with open circuit detection. 8 ch., 1 group of 8 ch., 0(4)-20 mA, 12 bits, load: max 725 Ω (short-circuit-proof). 

AO895 Analog outputs with HART interface & open circuit detection. 8 ch., 1 group of 8 ch., 4-20 mA, 12 bits, HART interface, load: max 725 Ω (short-circuit-proof).


S800L I/O modules

DI801 Digital inputs. 16 ch., 1 group of 16 ch., 24 V d.c., current sink. 

DI802 Individually galvanic isolated digital input channels. 8 ch., separate returns, 110 V d.c., 120 V a.c. 

DI803 Individually galvanic isolated digital input channels. 8 ch., separate returns, 220 V d.c., 230 V a.c. 

DO801 Digital outputs. 16 ch., 1 group of 16 ch., 24 V d.c., max 0.5 A, transistor, current source, short-circuit-proof. 

DO802 Individually galvanic isolated digital output channels. 8 ch., separate returns, 24-250 V, max 2 A a.c./d.c., relay (N.O.). 

AI801 Analog inputs. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA, 12 bits. 

AO801 Analog outputs. 8 ch., 1 group of 8 ch., 0(4)-20 mA, 12 bits, load: max 850 Ω (short-circuit-proof).


S800 I/O modules for redundancy

DI840 Digital inputs with SOE. 16 ch., 1 group of 16 ch., 24 V d.c., current sink, extended diagnostics, transmitter power supply. 

DP840 Pulse counters with wire-fault detection. 8 ch., 1 group of 8 ch., freq. measurement or pulse counting, 0.5-20 kHz,12/24 V d.c or NAMUR, extended diagnostics. 

DO840 Digital outputs with short circuit detection. 16 ch., 1 group of 16 ch., 24 V d.c., max. 0,5 A, current source, short-circuit-proof, extended diagnostics. 

AI843 TC inputs with open circuit detection. 8 ch. + ref. junction, 1 group of 8 ch., TC types: B, C, E, J, K, L, N, R, S, T, U, -30…75 mV, 16 bits, extended diagnostics. 

AI845 Analog inputs with HART interface. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA 0(1)-5 V, 12 bits, extended diagnostics, HART interface, transmitter power supply. 

AO845A Analog outputs with HART interface & open circuit detection. 8 ch., 1 group of 8 ch., 4-20 mA, 12 bit, load: max 750 Ω (short-circuit-proof ) extended diagnostics, HART interface.


S800 I/O modules for SIL3

DI880 SIL3 digital inputs with SOE. 16 ch., 1 group of 16 ch., 24 V d.c., current sink, extended diagnostics, transmitter power supply, SIL3. 

DO880 SIL3 digital outputs with wire-fault detection. 16 ch., 1 group of 16 ch., 24 V d.c., max. 0.5 A, current source, short-circuit-proof, extended diagnostics, SIL3. 

AI880A SIL3 analog inputs with HART interface. 8 ch., 1 group of 8 ch., single ended with common return, 0(4)-20 mA, 12 bit, extended diagnostics, HART interface, transmitter power supply, SIL3.