51204172-175 | Honeywell Analog Output Module

  • Warranty: 365 days
  • Quality: Original module
  • Condition: New / Used
  • Warehouse: Spot
  • Delivery time: Shipped in 3 days after payment
  • Mailbox:panda@xiongbaindustrial.com

.Many products are not yet on the shelves please contact us for more products

.If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation

.We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible


51204172-175 | Honeywell Analog Output Module belongs to the MC-TAOY22 series and is a DCS system module. The following is a more detailed description:

System: It can be applied to Honeywell's MasterLogic-200 PLC and other systems, and undertakes analog signal output and other related functions in the entire system architecture.

Functional features

Input and output functions: It has 32 input channels and 16 output channels, the input voltage range is 15-30Vdc, and the output type is 4-20mA. It can meet the input and output requirements of various analog signals and can be widely used in industrial scenarios that require precise control and monitoring of analog quantities.

High precision and stability: The output has high precision and stability, such as the output ripple is only 100mV peak-to-peak, the output temperature stability reaches ±0.02% full scale/°C, the humidity effect is only ±0.1% full scale (50% RH±40% RH), and the output current linearity reaches ±0.05% rated value, etc. It can maintain stable output performance under different environmental conditions and ensure accurate control of the system.

Fault protection function: It has a default output action in the event of a fault, and can choose to maintain the current output or power off, which helps to ensure the safety and stability of the system in the event of a fault, and avoid damage to the equipment or production process caused by abnormal output due to the fault.

Flexible control function: It supports software calibration, has modes and related functions that support manual loaders and direct digital control (DDC), and provides flexible control methods, which facilitates users to calibrate the module through software programs without complex hardware adjustments. Operators can choose manual or automatic control mode according to actual needs, which improves the operability and adaptability of the system.

Application areas: It can be applied to many industrial fields such as chemical industry, petroleum, building materials, aerospace, and electrical engineering. As long as it involves a system that needs to collect, process, and output control of analog signals, this module can be used, such as the control of parameters such as temperature, pressure, and flow in the chemical production process, and various data monitoring and control in oil extraction and refining.

51204172-175..jpg

Performance parameters

Input channels: 32.

Input voltage range: 15-30Vdc.

Output type: 4-20mA.

Output channels: 16.

Output ripple: 100mV peak-to-peak at power frequency, across 250Ω load.

Output temperature stability: ±0.02% full scale/°C.

Output readback accuracy: ±4%.

Humidity effect: ±0.1% full scale (50% RH±40% RH).

Output current linearity: ±0.05% rated.

Resolution: ±0.05%.

Calibrated accuracy: ±0.35% (25°C) including linearity.

Directly settable output current range: 0mA, 2.9mA to 21.1mA.

Absolute maximum current output for AO value digital input code: 24mA.

Maximum resistive load: 750Ω@20mA.

Maximum output compatible voltage: 15V.

Output settling time: 4ms for digital input.

51204172-175...jpg

Functional characteristics

Readback check of actual output current: The actual output current can be read back to ensure the accuracy and stability of the output, which is convenient for operators to monitor the output current status in real time and detect abnormalities in time.

Output characterization (5 segments): The output characteristics are divided into 5 segments, which can adjust and control the output more finely to meet the precise control requirements in different industrial scenarios.

Output default action on failure (hold or unpowered): In the event of a fault, there is an output default action, which can choose to keep the current output or power off, which helps to ensure the safety and stability of the system in the event of a fault, and avoid abnormal output caused by the fault from causing damage to the equipment or production process.

51204172-175.jpg

51204172-175 | Honeywell Analog Output Module




CUSTOMERS WHO PURCHASED THIS PRODUCT ALSO VIEWED THESE PRODUCTS:

HONEYWELL 05701-A-0301 | SINGLE CHANNEL CONTROL CARD

HONEYWELL CC-PCNT01 | 51405046-175 | Controller Module

Honeywell CC-IP0101 ProfiBus DP-2 Gateway Module 51410056-175

Honeywell 51197564-100 UCN Fiber Optic Extender

Honeywell SC-UCMX02 51307198-276 CONTROLLER

Contact Us

Contact: Panda

Phone: +86 18106083673

Tel: +86 18106083673

E-mail: panda@xiongbaindustrial.com

Add: Unit A, Vision Center, 1733 Liling Road, Siming District, Xiamen, Fujian, China