Home >Product >DEIF

DEIF DELOMATIC SCM-1 POS 1044220100F Synchronizing Module

  • Warranty: 365 days
  • Quality: Original module
  • Condition: New / Used
  • Warehouse: Spot
  • Delivery time: Shipped in 3 days after payment
  • Mailbox:panda@xiongbaindustrial.com

.Many products are not yet on the shelves please contact us for more products

.If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation

.We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible


DEIF DELOMATIC SCM-1 POS 1044220100F Synchronizing Module The SCM-1 module consists of three boards connected by an eight wired bus on the front side (not the backplane bus). The boards for SCM-1 are named SCM-A, SCM-B and SCM-C and these names can be found on the boards. 

DEIF DELOMATIC SCM-1 POS 1044220100F

SCM-A board:

 Two relay-boards OPR-1 can be mounted.

 One for output for a mechanical speed governor (instead of electronic speed governor), and one

for outputs for mechanical voltage regulation (instead of electronic voltage regulation).For replacement of OPR-1 the screw for holding SCM-A must be removed, replace the OPR-1

modules, mount SCM-A ag


www.plc-module.com

SCM-B board:

 DIP switches:

 The I/O address for the backplane bus of the rack is to be set. Notices that all SCM-1, SCM-2 and

PRM-1 modules must have different I/O addresses starting with number zero (null) and up to two.

The number sequence can be interrupted. The I/O address is set by the S2 switch. 


SCM-C board:

 DIP switches:

 The voltage measuring range is selected by jumpers on this board.

 For generator voltage the measuring range is selected by jumpers X5, X6, X7 and X8 and for the

busbar voltage the measuring range is selected by jumpers X10, X11, X12 and X13 (one jumper

for each phase and the 0-conductor. 


Replacement instruction ñ SYNCHRONIZING/MEASURING MODULE SCM-1 Placement of I/O addr./ jumpers SCM-B DELOMATIC Placement of I/O addr./ jumpers SCM-C DELOMATIC Replacement of OPR-1 modules



PCM4-1
PCM42
PCM43
PCM44
PCM5-1
PPU2
RMC-111D
RMC-131D
RMC-131D/2
RMF-112D
RMV-112D
SCM-1
SCM41
SCM4-1
SCM42
SCM4-2
SMC-C
TAC-311DG
TAP-210DG/3
TAS-331DG


Mailbox:plc-module@foxmail.com  | DEIF SCM-1,1044220100F
www.plc-module.com   | XiongBa Industrial Control | Panda +86 18106083673



Contact Us

Contact: Panda

Phone: +86 18106083673

Tel: +86 18106083673

E-mail: panda@xiongbaindustrial.com

Add: Unit A, Vision Center, 1733 Liling Road, Siming District, Xiamen, Fujian, China